All are comprehensively tested to british standard to ensure they meet their design criteria. All fplp cable are listed as having adequate fire resistant and lowsmokeproducing characteristics. The cable is exposed for 15 minutes to flame at 650c and for additional 15 minutes to fire and water spray. Single core and multicore cable with copper conductor, mica tape, xlevami compound and lsoh sheathed. Firetuf ft 120 enhanced fire resistant cable firetuf ft120 is the enhanced fire resistant cable solution for fire detection, fire alarm, emergency voice communication and emergency lighting circuits. Superior essex has grouped its fire alarm cable products into just two categories for simplicity. The german standard specifies that the entire system of cable trays, accessories and cables must be tested in an oven which is at least 3 m long for a period of 30, 60 or 90 minutes at temperatures of up to c. A vertical 600 mm long cable will be burned with 1 kw propane gas burner.
They provide information on how fire spreads along the cable as well as on the potential threats to people and materials in the event of a cable fire. Flame retardant and fire resistant cable flame retardant cable the flame retardant cable is mainly featured in low liability of fire or that second combustion is only limited to a certain range, meets the iec60332 combustion testing requirements, and is applicable to the places with flame retardant requirement. Fire resistant lszh cables ph 90120180 elettronica. The cable is exposed to fire at the 950c for 180 minutes. Fire retardant cable passed smallscale certification to protect against the spread of existing fire and but has not earned the fire rated certification.
A major contribution towards overcoming these hazards is the use of fire resistant and non halogenated cables. This range corresponds to the pyrobelca cables of 150v or 0. Fire resistant cables fire resistant cables the resistancetofire is the term used to describe how long a cable continues to operate in a fire. The use of the appropriate bicon gland or cleat is recommended. Lszh fire resistant cables 300500v singlecore 4core mica tape fire barrier, xlpe insulated, lszh sheathed, fire resistant cable cumicaxlpelszh application. Fireproof wire and cable is a general name for the fire resistance wire and cable, usually divided into flame retardant wire and cable zrbv and fire resistant wire and cable nhbv. All riser listed fire alarm cables provide full compliance to nec article 760, nec article 725, fplr and cl3r.
This may be of primary concern, for instance, in life safety of fire fighting installations. E resistant cables prysmian fp600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire survival requirements now requested by regulators and specifiers for many fire fighting and life safety applications. A flameretardant cable is designed only to restrict the spread of a fire by inhibiting combustion. Fire survival resistant cables manufacturers in india. Global expert in cables and cabling systems, about nexans, nexans in china, nexans companies, nexans yanggu new rihui cables co. Standard fire resistant cable bs76291 lpcb basec approved. Low smokes cables have a sheath designed to limit the amount of smoke and toxic halogen gases given off during fire situations.
A medium voltage fire resistant cable has been developed and tested exceeding existing fire performance requirements. Difference between flame retardant cable and fire resistant release time. Fire resistant cables come in a variety of types and standards. Standard fire resistant cable bs76291 lpcb basec approved standards bs 58391. Specification for 300500 v fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire. These cables are third party approved by lpcb according to bs 7629 that includes bs 6387 cat. In the workplace, control rooms, civil buildings, means of transport, it is important for signalling or connection cables to continue operating even in case of fire.
Print recommend this page lpcb approved ajh cables. Specifications ul 2hour rated fire resistive ci alarm. The cable is exposed to a flame at 930c and mechanical shocks for 60 minutes and additional 60 minutes to flame, mechanical shocks and water spray. Fire resistant lszh cables ph 90120180 elettronica conduttori. In addition to maintaining circuit integrity during a. Fireflex fire resistant cables alarm systems, together with the power supply to transport facilities and elevators. At present, in cable industry, fire retardant, low smoke halogen. Difference between flame retardant cable and fire resistant. Fire resistant cables are designed to be used in safety systems emergency lighting, fire detection, warning systems, door opening, etc.
Low voltage cables, fire retardant, fire resistant, low smoke, halogen free. Fire resistant and fire retardant cable sheaths are design to resist combustion and limit the propagation of flames. The materials used in halogenfree cables are easy to recycle. The main purpose of this study is to describe the need for an improved fire resistant cable solutiondesign to demonstrate. It is the investment in innovation that ensures draka products meet or surpass the requirements of the latest fire rated cable performance standards.
Fire class description reka cables ltd cable solutions. Samples of cables 3,5 m long in quantities required by standard are. Fire resistant flamerex cables from reka cables are suitable for applications where power supply needs to be secured, also during a fire. Fire alarm cable commercial applications unshielded, power. Fire resistant cables are halogenfree, and do not contain any pvc or spread fires when used in a bundle. Alantek fire resistant control cable consists of bare copper conductor with mica tape, xlpe insulation, with or without aluminium foil and outer lszh jacket. Fire resistant cables fire resistant cables fp400 bs7846f2 installation fp400 appr ovals prysmian fp400 is the original fire resistant armoured cable providing an easy to install and terminate, robust fire resistant wiring system. The fp cables range of fire resistant cable contains cables for most fire applications from a fire resistant alternative to standard cable for use in metal conduits and trunking, to more.
Fireresistant cables are halogenfree, and do not contain any pvc or spread fires when used in a bundle. In addition to the tests decribed for lshf cables following tests are intended to evaluate the circuit integrity of the cable. About 8% of these are control cables, 20% are power cables, and 38% are electrical wires. The cable is mounted on a vertical panel and shocked with a steel bar for 15 minutes while submitted to the action of a flame. The nexans fire protection kit is designed for easy installation due to the belt design. Multicore fire resistant, halogen free lszh cables fte4om1 cei 20105 multicore fire resistant, halogen free lszh cables for voice alarm en 50200. Fire resistant cables bs 84342 standard cable bs 58391 clause 26. Nexans fire resistant cable blanket is a cable joint protection cover with belts designed to be used with lv, mv or hv joints and cables in applications where low smoke emission and resistance to fire is needed. Fire resistant cables bs 84342 enhanced cable bs 58391 clause 26. Fire resistant cables fire performance, fire survival cable. Fire resistant cables fire performance, fire survival.
The best safety and rescue equipment cannot work without secured power supply. Shielded multiconductor fplrcmg ft4 rated product description bare copper conductors, pvc insulation. Free lszh, low smoke fume lsf and fire resistant cables are all described as fire. Contact our technical team to discuss your specific project or applications requirements. Testing methods for fire resistant cables the most critical cables must be fire resistant. Whether its cable operation within a furnace or during a fire emergency, security is always a high priority. Specifications ul 2hour rated fire resistive ci alarm cables. Ul 2196 standard for fire test for circuit integrity of.
Standards for fire resistant cablesfireproof cables. Fireresistant cables reka cables ltd cable solutions for. Old swedish testing method, where the cable is installed to a vertical tube. As a leading supplier of fire performance cable, we have vast experience of designing and supplying cables manufactured in accordance with british, european and international standards. Alantek fire resistant control cable consists of bare copper conductor with mica tape, xlpe insulation, with or without aluminium foil and outer lszh jacket replace frs to fru for unshielded solution. Fire resistant cables fp200 flex plain annealed copper stranded circular conductor complying with bs en 60228 class 2.
Fire resistance means that the cable is guaranteed to work even during a fire. Fire alarm cables are used for a variety of life safety devices, and are required to comply with many codes and standards. Fire resistant cables fireguarduk fg frc 180 ph30 fireguard cables are manufactured with latest technology to ensure consistent quality and reliability. Plain annealed solid copper to bs en60228 and iec60228 up to 2. Fire resistant enhanced cable fire resistance cables enhanced 300500v bs76291, bs58391. National electrical code, andor the national fire alarm and signaling code, andor the standard for fixed. This is made possible by special insulation material, which is merely altered rather than destroyed by fire. Fire resistant alarm cables je fire alarm cable bd unit stranding. This site uses cookies so that we can provide you with the best user experience. This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply.
Fire resistant cables companies ifsec global directory. Fire resistance means that the cable or the cable system where the cable is installed is capable to continue to operate even in case of fire for a specific period of time from 30 to 180 minutes. In addition to maintaining circuit integrity during a fire, fp400. Jul 19, 2016 given the operative difference in cable rating systems, here are the key essentials. These cables are designed to continue to operate for a period of time in a fire situation. In former times the cable industry had only limited options for fire resistant cables with fulfil ment of e. It meets the requirements of the construction standard bs76291, certified by basec and also meets the enhanced requirements for. Fire resistant cable in all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. Additionally, fire resistant cables can be used to replace expensive fire rated structures, blankets or wraps and the difficult to install mi cable. Type fplp fplp powerlimited fire alarm cable is listed by the nec as being suitable for usein ducts, plenums and other space used for environmental air.
Fireresistive cables maintain circuit integrity and continue to work for a specific time under defined conditions such as fire. There is still no european standard on fire resistance specifically for cable trays. Fireresistant flamerex cables from reka cables are suitable for applications where power supply needs to be secured, also during a fire. Fire resistant enhanced cable telephone cable cable. Fire resistant cable for the petrochemical industry. Our fire performance cables are specifically designed for augmented fire resistance in applications including the delivery of power and auxiliary control in fire alarm systems, voice alarm systems, and emergency lighting systems including those applications designed to meet bs5266. Fireresistant cables reka cables ltd cable solutions. This includes approval to bs en 50200 class ph120 and the new integrated. Multipairs, layers, individual and collective screen, stranded conductor. At the end of the test the burnt portion of cable must not be 50 mm close to the higher clamp. Installing the correct tested and certified cable is essential when considering safety issues that involve fire.